Characteristics
The LCI series consist of an external Inverter unit connected to 3 types of internal units
- LCI: 8 sizes of different capacity with single phase power
- LCI_T: 4 sizes of different capacity with three phase power
Internal Unit
- Cassette (False ceiling mounted) (600×600):
LCI036CS – 051CS
(It is required to connect with accessory LCIGL40S)
- Cassette (False ceiling mounted) (840×840):
LCI071C – 086C – 101C -121C
(It is required to connect with accessory LCIGL40)
- Cassette (False ceiling mounted) (910×910):
LCI141CB – 161CB
(It is required to connect with accessory LCIGL40B)
- Floor Ceiling (Wall or ceiling mounted):
LCI026F – 036F – 051F – 071F – 086C – 101F – 121F – 161F
- Ducted (Horizontal installation):
LCI026D – 036D – 051D – 071D – 086D – 101D – 121D – 141D – 161D
- Refrigerant R410A
- Heat pump operation with reversible refrigerant cycle and defrost control
- The DC Inverter compressors are selected to maximise efficiency, reduce consumption and minimise starting current
- External unit fitted with one or two fans with DC Inverter motor with continuous speed control
- Internal unit with 3 speed fan assembly
- Wired panel and remote controller standard on all internal units
- Infrared remote controller with liquid crystal display to control all functions
- Wired panel with liquid crystal display to control all functions
- Microprocessor control
- Possibility to set the ambient temperature sensor in the intake of the internal unit or in the wired panel
- Timer for programming switch on or off
- Operating modes: Cooling, Heating, Dehumidification, Automatic or Ventilation Only
- Extremely low noise operation
- Auto-Restart function: restart as default, can be deactivated
- Condensate discharge pump in version LCI_C-CS-CB
- Simple installation and maintenance • Air filter easily removed and cleaned • Flare type refrigerant connections
- Maximum refrigerant line lengths:
- up to 20m for units LCI026, LCI036 and LCI051
- up to 30m for units LCI071, LCI086, LCI101, LCI101T
- up to 50m for units LCI121, LCI121T, LCI141, LCI141T and LCI161T
- Condensation control device standard; allows operation in Cooling with external temperatures down to -15°C