Characteristics
Reversible Heat pumps units
Versions
ANK H: Heat pumps high efficiency, withouthydronic kit
Versions with hydronic kit
ANK_HP: with standard pump
ANK HA: with buffer tank and standard pump
- Operationallimits(1)
- max. external air temperature 46°C cooling mode
- max. Leaving water temperature 60°C heating mode
- High efficiency scroll compressors with low power input
- Electronic soft start to reduce starting current (standard for single phase versions)
- High efficiency heat exchangers with trace heating as standard flow switch as standard supply
- Water filter
- Axial flow fan units for extremely quiet operation
- Inverter axial flow fan units for heat pumps (ANK020H÷ANK085H)
- The hydronic kit includes: – Expansion tank
- Safety valve
- Pressure gauge
- Electronic controller (Modu_control)
- Metallic protective cabinet with anti-corrosion polyester paint
(1) For more details on operating limits, refer to the technical documentation available on the website www.aermec.com
Accessories
- MODU-485BL: RS-485 interface for supervision systems with MODBUS protocol.
- AERSET
The AERSET accessory allows the automatic compensation of the operating setpoint of the unit to which it is connected, based on a 0-10V MODBUS input signal. Mandatory accessory: AER485 or MODU-485A
- AERWEB300: The AERWEB option allows remote control of a chiller through a standard PC and an ethernet connection with a standard browser; 4 versions available:
- AERWEB300-6: Web server to monitor and remote control maximum 6 units on RS485 network;
- AERWEB300-18: Web server to monitor and remote control maximum 18 units on RS485 network;
- AERWEB300-6G: Web server to monitor and remote control maximum 6 units on RS485 network with integrated GPRS modem;
- AERWEB300-18G: Web server to monitor and remote control maximum 18 units on RS485 network with integrated GPRS modem.
- MULTICONTROL: Allows the simultaneous control of several chillers or heat pumps (up to 4) fitted with our MODUCONTROL controller and installed in the same hydraulic system.
For complete control the following accessories are available:
- SPLW: System water temperature sensor. In most cases the loose supplied sensors for each chiller/ heat pump are sufficient. In cases of a common flow/return header this sensor can be used to control the common system supply water temperature for the chillers connected to the header, or it can be used for temperature monitoring.
- SDHW: Domestic hot water temperature sensor. Used with the storage tank to control the temperature of water produced.
- VMF-CRP to predict accessory for the management of the probes SPLW / SDHW if provided with the MULTICONTROL
- PR3: Simplified remote panel. Permits control of the basic unit functions (on/off and change of operating mode, diagnostics and alarm reset). Maximum distance permitted is 150 m with screened cable.
- DCPX: an speed controller allowing operation in cooling mode within an external temperature range from +20 °C to -10 °C; in heating mode in summer to produce DHW with external temperatures up to +42 °C.
- BDX: Condensate drip tray with integrated electric heater controlled by the external air temperature sensor.
- BSKW: Electric heater kit with IP44 panel for remote mounting in a sheltered area. Available in single and three phase power supply:
- BS4KW230M (4 kW, 230V/1/50Hz)
- BS6KW230M (6 kW, 230V/1/50Hz)
- BS6KW400T (6 kW, 400V/3/50Hz)
- BS9KW400T (9 kW, 400V/3/50Hz)
- VT: Anti-vibration mounts.
Accessories factory fitted only
- DRE: Electronic soft starter device reducing starting current by about 30%.
- KRB: Electric anti-freeze heater for the base. Prevents the formation of ice on the base.
Compatibility with the VMF system
For further system information please refer to the specific documentation.